Flir Thermal Imagers In Malaysia
Sub Categories
Measure temperature from Thermocouple output Simulate Thermocouple output Operable with nine types of thermocouples Calibrate linear Thermocouple transmitter with mV source function Selectable °F or °C Thermocouple mini-jack termination
Measure loop current (0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution Measure voltage output process signals from PLCs, transmitters Source or simulate 24 mA loop current Source voltage to 100 mV or 10V 24V loop supply with simultaneous current measurement Enhanced voltage and current measure and source accuracy Improved battery life 250 ohm HART resistor with loop power Holster features test lead storage Compatible with toolpack magnetic hanging system Step and linear ramp output function Configurable zero and span settings
General Features: Measure pressure and vacuum to 0.05% of full scale with internal 30 or 100 psig sensor 1/8 NPT pressure fitting Compatible with non-corrosive gasses and liquids Measure pressure to 10,000 psi/69 mPa using one of 29 Fluke 700Pxx Pressure Modules Measure mA with 0.025% accuracy and 0.001 mA resolution, while providing 24 volt loop power New built-in pressure switch test feature Min/Max/Hold functions Fluke 718 Features: Built-in pressure/vacuum hand pump, with vernier and bleed valve Pressure and vacuum measurement to 0.05% of full span, using an internal pressure sensor (dry air only)
ATEX II 1G EEx ia IIC T4 Compliant Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve Pressure measurement to 0.05% of full span, using an internal pressure sensor Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules Wide range of selectable measurement units for pressure Current measurement with 0.02% accuracy and 0.001 mA resolution Pressure switch test function Min-Max Hold functions Simple, push-button user interface Rugged and reliable, ideal for field use
General Features: Electric pump for one handed pressure calibration Best in class pressure measurement uncertainty of 0.025 % Measure and source mA with best in class 0.015 % accuracy Precision pressure adjust vernier Variable release rate bleed valve for easy pressure adjustment Ideal performance for high accuracy transmitter calibration 30 PSI and 100 PSI pressure ranges Programmable pump limit: Eliminates over-pressurization Allows the user to program target pressures for pumping Extended measurement range with any of twenty-nine (29) 700Pxx Pressure Modules Source mA with simultaneous pressure measurement to test valves and I/Ps Simulate mA signals to troubleshoot 4-20 mA loops Test pressure switches with built in switch test function Power transmitters during test using 24 V loop supply Proven cleanout ports reduce pump failures
Electric pump for one handed pressure calibration Eliminate the need for a separate hand pump Best in class pressure measurement uncertainty of 0.025% Measure and source mA with best in class 0.015% accuracy Precision pressure adjust vernier for accurate pressure calibration Variable release rate bleed valve for easy pressure adjustment Ideal performance for high accuracy transmitter calibration 30 PSI, 150 PSI and the long requested 300 psi (2, 10 and 20 bar) pressure ranges Programmable pressure calibrator pump limit: Eliminates overpressurization Allows the user to program target pressures for pumping Built-in electrically driven pump capable of generating 300psi. Extended pressure measurement range with any of 29 700Pxx Pressure Modules Source mA with simultaneous pressure measurement to test valves and I/Ps Simulate mA signals to troubleshoot 4 20 mA loops Test pressure switches with built in switch test function Power transmitters during test using 24 V loop supply with simultaneous mA measurement Proven cleanout ports reduce pump failures Moisture trap included with the unit helps mitigates risk of moisture damage
Two isolated, stainless steel, pressure sensors with 0.025% F.S. accuracy 14 available pressure range configurations standard Temperature-compensation ensures accuracy in field applications External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) Requires 720RTD probe sold separately as an accessory Measure 4-20 mA signals Internal 24 V Loop Power Supply can power a transmitter under test Measure up to 30 V DC Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs) Ideal for gas flow calibration (custody transfer) applications Pressure displayed in the user’s choice of 19 engineering units Switch test on both Pressure inputs, or external pressure module Operating mode layers support simple measurements to complex applications Up to five frequently used setups can be stored; last setup automatically recalled on power-up % Error and damping functions
Easy to read dual display lets you view input and output simultaneously Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters Perform fast linearity tests with 25% and 100% steps Execute remote tests with auto step and auto ramp Power transmitters during test using loop power supply with simultaneous mA measurement Store frequently-used test setups for later use Compact, streamlined shape makes it easy to carry Rugged, reliable design stands up to field use Backlight lets you work in poor light Large battery capacity of four AA cells Battery door for easy changes