Flir Thermal Imagers In Malaysia

Sub Categories

  • Filter
Category: Calibrators

Support flow meter testing with frequency and CPM functions Perform fast linearity tests with auto- step and auto-ramp features Power transmitters during test using loop supply with simultaneous mA measurement Store frequently used test setups for later use Backlight lets you work in poor light Large battery capacity of four AA cells Battery door for easy changes Also available Fluke 725EX Intrinsically safe model

Category: Calibrators

Support flow meter testing with frequency and CPM functions Perform fast linearity tests with auto- step and auto-ramp features Power transmitters during test using loop supply with simultaneous mA measurement Store frequently used test setups for later use Backlight lets you work in poor light Large battery capacity of four AA cells Battery door for easy changes Also available Fluke 725EX Intrinsically safe model

Category: Calibrators

More precise measurement and calibration source performance, accuracies of 0.01% Transmitter error% calculation, interpret calibration results without a calculator Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis Frequency totalizer and frequency pulse train source mode for enhanced flow meter testing HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation Integrated pressure switch test allows you to capture the set, reset and deadband of a switch Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement New voltage input protection design for improved reliability Two separate channels; measure, source and view process signals simultaneously Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules Source mA with simultaneous pressure measurement to conduct valve and I/P tests Perform fast linearity...

Category: Calibrators

Multi-Function Calibrate temperature, pressure, voltage, current, resistance, and frequency Records and documents results Supports ISO-9000 or regulatory standards by capturing calibration results The USB interface lets users transfer the results to a PC Supports popular instrumentation management SW: The 753 works with the Fluke DPCTrack 2 software, and with popular programs from Honeywell Meridium, Emerson, Cornerstone, Yokogawa, Prime Technologies, Intergraph and others Three operating modes: Measure, Source, or simultaneous Measure/Source Bright, white display Rugged and reliable For a HART compatible Calibrator, Please Check the 754 Process Calibrator w/ HART Calibration

Category: Calibrators

Sources and measures dc voltage, current, resistance, RTDs and thermocouples Precision pressure measurement using Fluke 700 or 525A-P series pressure modules Includes 24 V dc transmitter loop power supply Measures 4-20 mA loop current Includes automated switch-test function Accepts ITS-90 coefficients for accurate SPRT measurements Compatible with MET/CAL Calibration Software

Category: Calibrators

Measure mA signals for PLC and control system analog I/O Measure 4 to 20 mA output signals from transmitters without breaking the loop Best in class 0.2 % accuracy Resolution and sensitivity to 0.01 mA Hold function captures and displays changing measurements Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight

Category: Calibrators

Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O Measure 4 to 20 mA signals with in-circuit measurement Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life

Category: Calibrators

DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing